Polyaluminium Chloride PAC Powder for Sewage Treatment and Potable-Water Qualification Enquiries

Share
Product description
  • Color
    Yellow
    Physical form
    Powder
  • CAS No.
    1327-41-9
    Purity
    28%-30%
  • pH Value
    3.5-5.0
    Adsorbent Variety
    Other
  • EINECS No.
    215-477-2
    Molecular Formula
    [Al2(OH)nCl6-n]m
  • State
    Powder
    Water Treatment Scenario
    Wastewater Treatment
  • Product Type
    Flocculant / Coagulant
    Dosage
    5-30 mg/L
  • Effective Concentration (%)
    28%-30%
    Ionic Type
    CATIONIC
  • Product Name
    Polyaluminium Chloride (PAC)
    Type
    Water Treatment Chemical
  • Appearance
    Yellow Powder, Light Yellow Powder
    Active Ingredient Content
    Al2O3 28% / 30%
  • Grade Standard
    Industrial Grade Drinking Water Grade
    Basicity
    Al2O3 ≥28% / ≥30%
  • Application
    Water Treatment,Wastewater Treatment,Drinking Water Purification
    Packing
    25kg Bag / 1000kg Jumbo Bag
  • Sample
    Available
    Storage
    Store in Cool, Dry and Well-Ventilated Place

Choosing a PAC sample for sewage treatment starts with identifying the exact material grade. This polyaluminium chloride is a cationic yellow or light yellow powder identified as a flocculant/coagulant. Its reported material pH is 3.5–5.0, with the preparation method still needed for comparison.

Confirm the alumina grade before setting concentration criteria

Request the exact grade declaration and current alumina analysis for the sample supplied. Confirm the reporting basis and the acceptance limit needed by the project. Do not assume that a broad content description identifies the concentration of the particular powder being evaluated.

Separate basicity from the material pH result

Obtain a correctly defined measured basicity report as its own parameter. Ask how the pH sample was prepared and tested. A reported material pH does not establish the operating range for incoming sewage or determine the treatment conditions by itself.

Make the sewage trial specific to the water stream

Describe the actual influent and the results required for acceptance. Have the appropriate technical team compare the sample through a controlled treatment assessment. Chemical identity and grade labels do not establish a universal dose or guarantee a removal result.

What is required for a potable-water enquiry?

Request the applicable grade and approval documents for the exact material before considering that use. Review them separately from the sewage-treatment trial. Keep current alumina, basicity and pH reports associated with the powder actually tested, then assess the project results and supplied storage instructions before final acceptance.